啪啪免费视频,啪啪啪app软件下载,啪啪啪网站

Welcome to the official website of Kangliang Electromechanical Equipment Co., Ltd.!

Favorite Kangliang | Contact Us

康亮机电

Kangliang Electromechanical Equipment Co., Ltd.

Rental of professional brand generator sets
康亮机电康亮机电

National Advisory Service Hotline: 136-7735-6587

Popular keywords: generator rental, generator rental price, used generator recycling, used generator rental, used generator rental price, used generator rental

东莞市康亮机电有限公司
Ranch
contact us
National Service Hotline: 136-7735-6587


Contact: Mr. Zhang


Phone: (0769) 87186846

186-8866-08l5 <Guangdong>

136-7735-6587 <National>

Address: Zhangyang Management Zone, Zhangmutou Town

Home > News> Industry News

Generator installation six major points to note

发表时间:2018-11-29 09:00:26 【 Popularity: 398 Time: 2018-11-29 09:00:26 [Large Middle Small]

Generator installation rental six major points to note:
First, the installation site should be well ventilated, the generator side should have sufficient air inlets, and the diesel engine side should have good air outlets. Air outlet area

It should be more than 1.5 times larger than the water tank area.
Second, the surroundings of the installation site should be kept clean, and items that can generate corrosive gases such as acid and alkali should be avoided in the vicinity. Have

Conditions should be equipped with fire extinguishing devices.
3. For indoor use, the smoke exhaust pipe must be led to the outdoor, the pipe diameter must be ≥ the diameter of the smoke pipe of the muffler, and the elbow of the connected pipe

Should not exceed 3 to ensure smooth smoke exhaust, and the pipe should be tilted down 5-10 degrees to avoid rainwater injection; if the exhaust pipe is installed vertically upward

, You must install a rain cover.
4. When concrete is used for the foundation, the level of generator rental must be measured with a spirit level during installation to make the unit fixed on a level foundation. Unit and base

There should be special anti-shock pads or foot bolts between the foundations.
5. The unit casing must have reliable protective grounding. For generators that need to be directly grounded at the neutral point, it must be carried out by professionals.

Neutral grounding and lightning protection device. It is strictly prohibited to use the grounding device of the mains to directly ground the neutral point.
6. The two-way switch for generator rental and utility power must be very reliable to prevent reverse power transmission. Wiring reliability of bi-directional switches requires local power supply

Department inspection and approval. http://hzbxx.cn/


Recommended Products
  • 500KW Power Generation Unit
    500KW Power Generation Unit
  • 450KW Power Generation Unit
    450KW Power Generation Unit
  • 50KW generator set
    50KW generator set
  • Jichai generator set
    Jichai generator set
  • Cummins 250KW generator set
    Cummins 250KW generator set
  • Cummins 200KW generator set
    Cummins 200KW generator set
  • Cummins 800KW generator set
    Cummins 800KW generator set
  • Cummins 600KW generator set
    Cummins 600KW generator set
  • Cummins KTA38 generator set
    Cummins KTA38 generator set
  • Cummins 1000KW generator set
    Cummins 1000KW generator set
  • Cummins 1200kw generator set
    Cummins 1200kw generator set
  • Yuchai generator set
    Yuchai generator set